Skip to content
Ultra NT SCIF Barrier • Call Michael Thrift 800-753-9090
Ultra NT SCIF Barrier • Call Michael Thrift 800-753-9090

Ultra NT SCIF Barrier Solid - Information Center

Find all the resources you need for Ultra NT SCIF Barrier - Solid below. If you have specific questions, please give as a call 1 (573) 817-9696 or send us an email.

Ultra NT SCIF Barrier - Solid has minimum shielding effectiveness of 91.7 dB measured between the frequencies of 30 MHz and 18 GHz.

 

Product Details

Ultra NT SCIF Barrier - Solid is designed to be used in Sensitive Compartmentalized Information Facilities (SCIF's). Ultra NT SCIF Barrier - Solid has a minimum shielding effectiveness of 91.7 dB measured between the frequencies of MHz and 18 GHz.

Ultra NT SCIF Barrier is a heavy-duty radiant barrier sheet made up of a single layer of woven polyethylene material bonded to and sandwiched between two highly reflective aluminum foil surfaces. In addition to being a highly effective radiant barrier, Ultra NT SCIF Barrier - Solid is also an approved vapor barrier.

Roll Size: 48" wide x 125' long (or 500 square feet per roll)

Product Specific Application: Sensitive Compartmented Information Facilities (SCIF's)

Product Features:
• Highly reflective radiant barrier surface
• Thermal performance unaffected by moisture
• Durable - yet flexible - woven polyethylene base
• Reflects 97% of Radiant Heat (with (1) adjacent airspace). Unrolls and cuts easily
• Increases sound attenuation for SCIF's

Installation Guidelines

*NOTE: The installation guidelines shown below are for information purposes only and do not take the place of the Architectural Specifications.

*NOTE: With regard to the Architectural Specification for any particular job, the appropriate products and installation methods to be used shall override information presented in the General Installation Guidelines.

1. Unroll the Ultra NT SCIF Barrier and cut it to the appropriate length to cover all walls, ceilings, and floors of the room or building that you want to be shielded from RF transmission, per the Architectural Specifications. The manufacturer recommends cutting the SCIF barrier 12" longer than the length of the wall, ceiling or floor to be covered to allow SCIF Barrier to wrap around corners.

2. Ultra NT SCIF Barrier may be attached to wood using staples (every 6"-10"), tape, general-purpose construction adhesive, or spray on contact adhesive per the  Architectural Specifications.

3. Ultra NT SCIF Barrier may be attache to steel studs using tape, general-purpose construction adhesive, or spray on contact adhesive per the Architectural Specifications. [Aluminum Foil Tape or 3M Conductive Tape)

4. Ultra NT SCIF Barrier may be attached to concrete using a general-purpose construction adhesive or spray-on contact adhesive per the Architectural Specifications.

5. Ultra NT SCIF Barrier may be attached to gypsum board using staples (every 6"-10"), general-purpose construction adhesive, or spray on contact adhesive per the Architectural Specifications.

6. When installing a second layer of gypsum board on top of Ultra NT SCIF Barrier, the manufacturer recommends using black phosphate fine thread drywall screws for panel installation, unless otherwise specified in the Architectural Specifications.

7. Ultra NT SCIF Barrier joints may be required to be butted together, overlapped, folded, and/or taped per the Architectural Specifications.

8.  When you reach the top of a wall, Manufacturer recommends extending the Ultra NT SCIF Barrier so that it wraps around the joint and onto the ceiling for 6" to 12"

9. When you reach the bottom of a wall, Manufacturer recommends extending the Ultra NT SCIF Barrier so that it wraps around the joint and onto the floor for 6" to 12"

10. Ultra NT SCIF Barrier material may or may not be installed on the ceiling and floor per the Architectural Specification, to complete the job.

11. If required, ground the Ultra NT SCIF Barrier enclosure per the Architectural Specifications. Grounding from any single point, separated from the electrical grounding for the building, has been shown to have a positive effect on Ultra NT SCIF Barrier enclosure performance.

If you have any questions, need written price quote or assistance place your order, please call (573) 817-9696.

MET Labs Testing Report

MET Laboratories, Inc.
Safety Certification - EMI - Telecom Environmental Simulation
914 West Patapsco Avenue
Baltimore, Maryland 21230-3432

Phone: (410) 354-3300
Fax: (410) 354-3313

November 17th, 2017

National Building Supply, Inc.
2000 East Broadway Suite 225
Columbia, MO 65201
Toll Free: 1 (573) 817-9696

The purpose of this letter is to inform National Building Supply, Inc. that the samples of Ultra NT SCIF Barrier - Solid provided to us on 11-30-2017 was tested at MET Laboratories, Inc., 914 West Patapsco Avenue, Baltimore, MD. All equipment used in making physical determinations is accurate and bears recent traceability to the National Institute of Standards and Technology. Testing evaluated using IEEE-299 guidelines.

Sincerely,

John Mason
Military Testing Manager, Electromagnetic Compatibility Lab

Reference: (\National Building Supply, Inc.\EMC90739-IEEE.REV2)

The Nation's First Licensed Nationally Recognized Testing Laboratory